SG Security Communications MLR2-E Manuel d'utilisateur Page 37

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 59
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 36
Form Number.: 7-3005 File Name: SG Automation Output Revision/Date: 01/May 3, 2005
Department: Engineering
Division: Embedded Software Form Template Owner: Jeff Cougler
37
4.25 DMP Protocol (P)
PRRLLLsAAAAAsXT
1
…T
n
s[DC4]
Where:
P = DMP protocol identifier
RR = Virtual receiver number
LLL = Virtual Line number
s = spaces
AAAAA = Account code.
X = DMP serial format identifier
T
1
-T
n
= Alarm Information
P01100 243 X002004N HALL MOT
Examples:
P01001s12345sA00081EASTsSMOKEs[DC4]
P01001s12345szA00085555116NORTH OFFICE PRI15S. WEST BUILDINGs[DC4]
The above two automation signals are both DMP Serial1 format. The 14
th
character in the above examples will determine if the
received format is Serial1 or Serial3. Following the account and a space, if this character is anything but an uppercase ‘Z’, the DMP
format is Serial1. If you look at the below signal, you will see that the 14t
h
digit is an uppercase ‘Z’, therefore the signal is Serial3
format.
P01001s12345sZa\61\tBU\z 0232”FRONT DOOR\a 03”OFFICE\u 0568”JOHN SMITH\[DC4]
NOTE: The position of the DMP Serial Format Identifier can change, depending of the line card number length.